Agf test and drain pdf files

Aliquots of sludge are treated oneatatime with different dosages of polymer solution. Fm approvals has been notified by agf manufacturing inc of the discovery of suspect counterfeit model ball valves manufactured in china. Lightweight and compact, the model testandrain is a 300 psi rated single handle ball valve that. Agf manufacturings collectandrain auxiliary drain product line for condensation collection. Model testa n drain provides both the test function and the express drain function for a wet fire sprinkler system. The agf model testa n drain provides the test and express drain functions for wet fire sprinkler systems nfpa, nfpa d, and nfpa r. Pressure relief valves can be installed on a testandrain valve without removing the valve from the line or draining the system completely. Features a cast body with shut off valve, test and drain valve combination and different sizes, flow switch, and a pressure gauge. Ul and fm state tha argco meets all of the specifications for fire. Read here what the afg file is, and what application you need to open or convert it. Since then, testan drain valves have been installed in countless systems throughout the world.

The purpose of the laboratory gravity drainage test is to select and quantify a treatment program for dewatering wastes containing greater than 1% suspended solids i. Do not assume there are any similarities with any other drains. Please specify valve and orifice sizes when ordering valve repair kits. Argco test and drain valve female npt inlet and outlet forged brass body large, integral sight glass on each side brass finish ball with teflon seats 12 nominal test orifice ul ulc listed, fm approved agf design files from these online resources. Is there a way where we could make postgis consume the agf files. Flowbuster for flow testing fire pumps, hydrants, standpipes inspection, testing, and maintenance equipment. The model 8011 r includes a flow switch, inspectorstest model 3011a, model 7600 3way universal valve, m7500 pressure gauge, and a model 7200 pressure relief valve. Agf manufacturing revolutionized the fire sprinkler industry with the model testandrain single valve inspectors test which eliminated the time and space consuming traditional loop assembly. Close the control valve again and leave the pipe for five minutes. During the water test, precautions should be taken to prevent any movement of the drain. Model 1011t testa n drain testandrain inspectors test. If after this time the pressure in the pipe has not dropped below 2. American reconstruction and reinvestment act of 2009 arra arra certification. The residential riserpack model 8011 is a riser assembly designed for nfpa r fire sprinkler systems that require pressure relief.

When not in the closed position, the valve can be either fully open full port, or tested through a 12 restricting orifice. Sectional floor control test and drain valve with pressure. Download agf design files from these online resources. All control, auxiliary, drain, and inspectors test valves located more than seven 7 feet. Series 747m firelock commercial zone control riser module. I came across term which says agf, after googling i found its autodesk geo files, but some other say, atlas geo files, which one of them is right. Model 1011t testa n drain matches all the features and benefits of our model by providing both the. Since then, testandrain valves have been installed on many fire protection systems throughout the world. Victaulic series 747m firelock commercial zone control riser. Usually, test water is released outside of the building wasting numerous gallons of water each test cycle. Model testandrain provides both the test function and the express drain function for a wet fire sprinkler system. Agf has valve repair kits available for replacing the ball and seats. Foreign material in the line can scar the ball and seats of a testandrain valve, allowing the valve to pass system water. The agf model 1011t testa n drain provides the test and express drain functions for wet fire sprinkler systems on multistory installations requiring pressure relief nfpa and nfpa r.

Argco test and drain valve female npt inlet and outlet forged brass body large, integral sight glass on each side brass finish ball with teflon seats 12 nominal test orifice ul ulc listed, fm approved and fill with water to point of overflow. Sectional floor control test and drain valve for systems requiring pressure relief valve. I also came to know that it is an extension to wkt format supported by postgis. The agf model 1011t testandrain provides the test and express drain functions for wet fire sprinkler systems on multistory installations requiring pressure. Lyncar fire protection products agf testandrain models, 1011 and 1011t info provides the test and express drain function in a multi story installation, for a wet fire sprinkler system model meets all requirements of nfpa, r and d tamper resistant test orifice, sight glass rated 300 psi orifice size. The model 3011bv inspector stest is a single handle bronze ball valve rated at 300 psi. Navod k instalaci a pouziti elektromagneticky ventil rada 400 jar top pro automaticke zavlazovaci systemy modely. The model complies with the requirements of nfpa, nfpar, and nfpad. Testa n drain agf revolutionized the industry with the model testan drain single handle ball valve inspectors test which eliminated the time and space consuming traditional loop assembly. The model test a n drain is available in a full range of sizes. The model 7000 can be purchased individually or as part of the 1011 kit with all necessary drainage piping and connections for use with all testandrain valves. The valve features two large and integral sight glasses allowing for maximum visibility when operated. Its a quick and easy procedure that can be accomplished without removing the valve from the line and involves less labor than changing out the valve. Viking supplynet fire technology seminar thursday, june 5th 2014.

The model 1011a features a model 7000 pressure relief valve with drain pipe, 3. The utd eliminates the need to utilize two separate valves and additional fittings to perform the test and drain functions. The polymeric core act as a pipe and is manufactured to compressive strengths that eliminate the need foreliminate the need for aggregate backfill. I havent found this information yet clearly anywhere in nfpa.

Cad plumbing valves and fittings arcat free architectural cad drawings, blocks and details for download in dwg and pdf formats for use with autocad and other 2d and 3d design software. The model 8611 includes a flow switch, testandrain model 2511a, model 7600 3way universal valve, and a m7500 pressure gauge. Drain rock, pea gravel and similar materials meet these requirements and are used extensively in some drainage applications. Division 08 30 00 specialty doors and frames division 08 31 16 floor doors gratings floor doors distributed by. Model 3011bv inspector stest is designed to perform the remote inspectors test function as required for dry pipe systems by nfpa, 2007 edition see reverse. The first step in the design of a proper filter system, either geotextile or sand and gravel, is to perform a particle size analysis of the soil at the drain depth in the field. The commercial riserpack model 8011 is a riser assembly designed for nfpa fire sprinkler systems that require pressure relief. Download a pdf version of our printed croker catalog. Inspectors test and drain valves for residential and commercial.

Observe and document the static pressure on the supply side and start test time on appendix 1. Agf testandrain bronze test and drain valve, 112 in, fnpt. Testandrain valves provide both the test function and the express drain function for wet fire sprinkler systems. Open the 2 main drain fully and watch the supply side calibrated pressure gauge to see how much lower the pressure drops. Open the control valve and allow the pressure to drop so the manometer reads 3. All orders must be received by agf manufacturing, inc. If the pipe fails this air test, run a water pressure test to check its seals again. The sewer or drain under test should be left filled with water for at least 2 hours during which no level drop should be observed to ensure that all piping and joints are not leaked.

1507 210 1364 1014 163 1468 550 68 89 1480 899 502 853 1396 1636 566 1525 185 1416 145 29 1246 1057 1134 911 551 841 1349 380 1398 1390 1336 1496 577 995 32 157 850 1299 1253 674 1028 1264 114